计算acoustic response case 时,报错job execution failed ;
在确保前部操作没问题的前提下,计算acoustic response case ,提示报错job execution failed;failed to started sysnoise process. 具体报错信息如下,希望大神能给热锅上的蚂蚁我指点一下XPR VERSION 13.3
Requested task is SYSNOISE sequential computation.
Working directory on server is E:\VL_Temp
Checking that the SYSNOISE launch script (E:\Program Files\LMS\LMS Virtual.Lab 13.3\VirtualLab\Sysnoise\5.6\bin\sysnoise_nogui.bat) exists on server...
OK
SYSNOISE log file on server is E:\VL_Temp\Lixueyuan2-994470-sysnoise.log.
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
xxxxxxxxxxxxJOB EXECUTION START
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
System for Computational Vibro-Acoustics
------------------------------------------------------------------------
SYSNOISE 13.3Windows_x86_64 DATE: 10-DEC-2020 22:26:11
Build Date: 25-FEB-2015
READING THE SET-UP FILE: E:\Program Files\LMS\LMS Virtual.Lab 13.3\VirtualLab\Sysnoise\5.6\bin\\..\res\SYSNOISE.STP
THE SYSNOISE PROFILE FILE NAME HAS NOT BEEN DEFINED.
STANDARD GRAPHIC DEVICE SET TO DEFAULT
PLOTTING GRAPHIC DEVICE SET TO SCREENDUMP
MEMORY IN USE = 800000 ( 0.003 Gb )
AVAILABLE MEMORY = 1021500000 ( 3.805 Gb )
FREE MEMORY = 1020700000 ( 3.802 Gb )
CREATING DEFAULT SYSNOISE MODEL FILE default.sdb
SYSNOISE ANALYSIS OPTION :
BEM INDIRECT VARIATIONAL UNBAFFLED FREQUENCY FLUID
SYSNOISE>SCL> ENVIRONMENT SECTION SETUP USRDIR 'E:\VL_Temp\' RETURN
SYSNOISE>SCL> ENVIRONMENT SECTION SETUP TMPDIR 'E:\VL_Temp\' RETURN
SYSNOISE>SCL> Open Model 1 File Lixueyuan2-994470-Acoustic.sdb Original Return
OPENING SYSNOISE MODEL FILE Lixueyuan2-994470-Acoustic.sdb
LOADING MODEL Exported VLModel
ERROR - Normal cannot be calculated
**** ERROR has occurred during computation ****
You may try to compute the solution in manual mode and try to attach the results afterwards.
Please check element: 334725 (internal number)
ERROR - Normal cannot be calculated
**** ERROR has occurred during computation ****
You may try to compute the solution in manual mode and try to attach the results afterwards.
Please check element: 337169 (internal number)
SYSNOISE>SCL> Extract Summary Return
SYSNOISE ANALYSIS OPTION :
BEM INDIRECT VARIATIONAL UNBAFFLED FREQUENCY FLUID
SYSNOISE SUMMARY INFORMATION
------------------------------------------------------------------------
Title...Exported VLModel
Date....10-DEC-2020 22:26:18
Number of dimensions...................... 3
Number of nodes........................... 405730
Number of elements........................ 405726
Number of material characteristics........ 1
Number of load cases...................... 1
Number of elements with velocity B.C.'s... 405726
Number of field points.................... 1350
------------------------------------------------------------------------
SYSNOISE>SCL> Environment Section SETUP BELL 'on' Return
SYSNOISE>SCL> Environment Section SETUP GEO_TOLERANCE '1E-006' Return
SYSNOISE>SCL> Parameter Model 1
PARAMETER>SCL> Physical
PARAMETER>
PARAMETER>SCL> Save Potentials Step 1
PARAMETER>SCL> Save Results Step 1
PARAMETER>SCL> Store Results none
STORE RESULTS>SCL> Return
PARAMETER>SCL> Near 2
PARAMETER>SCL> Far 5
PARAMETER>SCL> Quadrature 221
PARAMETER>SCL> Positive
PARAMETER>SCL> Return
Updating Model Parameters
SYSNOISE>SCL> Solve
SOLVE>SCL> Frequency 20 To 5000 LinStep 20
SOLVE>SCL> Return 同问 请问解决了么? 这不是提示你有两个单元有问题吗?你检查一下那两个单元的几何结构,可能需要修改一下